Finnish / Traditional Sauna
Nordic spruce and thermowood cabins with Harvia, Tylö or EOS heaters — 80–100°C dry heat, built to Dubai Municipality standards.
Read more
A commercial thermal suite is judged on something a domestic room never is: how many hours a year it is available. Equipment specified for domestic duty in a room used sixteen hours a day fails within months, and every failure is a closed door and a refunded membership.
Multi-zone / Multi-zone
We deliver wellness fit-out for hotels, gyms, clubs and residential towers across Dubai: single cabins through to full thermal suites combining sauna, steam, hammam, experience showers and cold plunge. The work is delivered with drawings, approvals, phasing and a documented handover, because a commercial client is buying a facility with a service life rather than a room. Part of our sauna and steam room installation practice in Dubai.
Domestic heaters and generators are designed for perhaps an hour of use a day. Put one in a gym running sixteen hours and the element life collapses. Commercial units cost more up front and cost dramatically less over five years, and we will not quote domestic equipment for a commercial room.
Generators, chillers and control gear positioned so an engineer can reach them without entering the guest area or closing the facility. Access hatches designed in, not cut later. This single decision determines whether routine maintenance is a quiet visit or a disruption.
Most of our commercial projects run while the facility stays open. That means agreed working hours, dust and noise containment, protected routes through public areas, and a programme built around your quiet periods rather than our convenience.
Wiring diagrams, equipment schedules, commissioning records, cleaning and chemical regimes, and a maintenance schedule your engineering team can actually follow. Facilities fail because nobody was told what the room needed, more often than because the equipment was poor.
| Stage | Scope |
|---|---|
| Concept and layout | Space planning, bather flow, capacity, equipment selection |
| Drawings | Layouts, elevations, sections, equipment schedules |
| Services coordination | Electrical loads, water, drainage, ventilation with MEP |
| Approvals | Authority submissions, landlord and operator consents |
| Construction | Tanking, joinery, stone, glazing, electrical, phased |
| Commissioning | Run-up, testing, balancing, sign-off records |
| Handover | O&M documentation, staff training, spares list |
| Aftercare | Maintenance contract with priority response |
| Facility | Usual specification | Programme |
|---|---|---|
| Gym sauna, single cabin | Commercial heater, high-traffic benching | 3-5 weeks |
| Gym sauna and steam pair | Two cabins, shared plant room | 6-9 weeks |
| Hotel thermal suite | Sauna, steam, hammam, plunge, experience showers | 12-20 weeks |
| Residential tower amenity floor | Sauna and steam per gender, plunge | 8-14 weeks |
| Recovery studio | Infrared rooms and cold plunges | 5-8 weeks |
Finnish saunas, steam rooms, Turkish hammams, Moroccan bath rooms, infrared cabins and cold plunge pools, backed by maintenance contracts.
Commercial wellness fit-out across Dubai, Abu Dhabi, Sharjah, Ajman and Ras Al Khaimah.
Duty rating, principally. Commercial heaters and generators are built for continuous operation rather than an hour a day, with heavier elements, better thermal management and serviceable components. Beyond that: bench timber selected for constant traffic, hardware rated for thousands of door cycles a month, drainage sized for washing down, and plant positioned for servicing without closing the facility.
Yes, and we usually do. Most of our hotel and gym projects are phased so that one area closes at a time, or so noisy work happens outside operating hours. It takes longer overall and it costs more, but it is far cheaper than closing a facility. We agree the phasing before work starts and build the programme around it.
Yes. Layouts, elevations, equipment schedules with model numbers, electrical loads and drainage requirements, coordinated with the main contractor or the building's engineering team. For hotel projects we also provide the operation and maintenance documentation at handover.
Fit-out approval through the relevant authority, landlord or mall management consent, and compliance with health and safety requirements for wet areas covering drainage, ventilation, electrical safety and accessibility. Hotels have additional operator standards. We prepare the submissions as part of the project.
A single commercial cabin is three to five weeks. A multi-room thermal suite with sauna, steam, hammam and plunge is typically twelve to twenty weeks depending on phasing, stone lead times and the approval route. We give a dated programme with the tender return.
Yes, and for a commercial operator it is essential rather than optional. Contracts typically cover monthly or quarterly attendance, generator descaling on a schedule matched to usage, priority response for breakdowns, and a stock of critical spares so a failed element does not close a room for a week.
Nordic spruce and thermowood cabins with Harvia, Tylö or EOS heaters — 80–100°C dry heat, built to Dubai Municipality standards.
Read moreFully tanked, tiled or acrylic steam rooms at 100% humidity — vapour barrier, fall-to-drain and generator sizing done properly.
Read moreHeated marble göbektaşı slabs, domed ceilings and radiant benches built by tilers who have done it before.
Read moreChillers sized for UAE ambient loads, holding 4–15°C through August without tripping into permanent duty.
Read moreQuarterly descaling, element checks and timber care — annual contracts that keep a room out of downtime.
Read moreTadelakt walls, heated treatment beds and steam supply for salons and villa wellness suites.
Read moreThirty minutes on site tells us more than an hour on the phone — and it is the only way to give you a price that does not move.